Everpure Water System ENVI RO User Manual

Installation and Operation Guide  
ENVI-RO™ High Efficiency Reverse Osmosis System  
Mineral Reduction System For Foodservice Applications  
IntroductIon  
The Everpure ENVI-RO™ Mineral Reduction System is a pre-  
engineered, pre-assembled Reverse Osmosis (RO) system designed  
to provide high purity water for multiple applications, such as  
premium espresso, coffee, blended beverages and steam, to name a  
few. It combines a number of water treatment technologies into one  
easy to install package. The system provides superior protection  
against taste and odor causing contaminants while removing dirt,  
particulates and dissolved solids that can foul or scale equipment.  
Initial System Production  
Water production depends on supply water pressure and temperature.  
See PERFORMANCE section (page 8) for normalized production.  
Inuent Water characteristics  
The following table lists the allowable operating range of various  
water properties within which the ENVI-RO™ will function  
properly.  
Total Dissolved Solids (TDS) 0-1,000 ppm (0-1,000 mg/I)  
pH  
5-10  
oPeratIng SPecIfIcatIonS  
Chlorine1  
Chloramines  
Turbidity  
Iron  
0-3 ppm (0-3 mg/I)  
0-3 ppm (0-3 mg/I)  
0-1 NTU  
Dynamic Operating Pressure: 25-80 psi (1.7-5.5 bar)  
Static Operating Pressure: 100 psi (6.9 bar)  
Operating Temperature 40-100°F (4.4-37.8°C)  
Connections  
0-1 ppm (0-1 mg/I)  
Inlet/Outlet: 3/8-inch OD tube (John Guest© Push-in)  
Concentrate: 3/8-inch OD tube (John Guest© Push-in)  
Electrical: 115 volt AC / 60 Hz / 1 Phase  
Ampere:  
1 Reverse osmosis membrane filter used in this system will be damaged by chlorine. An  
activated carbon filter should be provided with this system to protect the reverse osmosis  
membrane from chlorine attack. Influent chlorine should not exceed 3 mg/I.  
the system consists of 5 major components:  
1. 2SR-BW Water Conditioning cartridge  
2. Dual-Head booster pump  
3. MR-600 Reverse Osmosis (RO) membrane cartridge.  
4. 6-Gallon RO Water Storage Tank  
Stand-by: 0.2  
Flush:  
Run/Fill:  
0.5  
2.7  
Branch Circuit Protection: 15 or 20 AMP Ground Fault Protected  
Pre-Installation checklist  
1. Can the unit be mounted within a reasonable distance of the  
water supply and drain facilities?  
5. Control System with Power Supply  
The 2SR-BW Water Conditioning cartridge contains media that  
reduces the scaling tendency of hard water minerals found in many  
water supplies, extending RO membrane life.  
2. Is there an un-switched 115 VAC GFIC (ground fault interrupter  
circuit) protected receptacle available for powering the system?  
The Dual-Head booster pump increases the inlet pressure to  
maintain consistent permeate production, plus eliminates back-  
pressure on the permeate output. This innovative approach to both  
boosting and eliminating back-pressure allows for maximum system  
efficiency.  
3. Is there adequate clearance and support to install the unit  
and permit access for maintenance? The total system weight  
will vary based on model and storage tank selected. See  
specification table for approximate operating weights.  
4. Does the inlet water supply meet the requirements listed below?  
a. A minimum of 25 PSI pressure on a consistent basis  
b. Less than 1,000 ppm of Total Dissolved Solids (TDS)  
c. pH level between 7.0-9.0  
The MR-600 RO membrane cartridge contains a semi-permeable  
reverse osmosis membrane. Here, most dissolved impurities are  
separated from the water and flushed down the drain. The water  
that is able to pass through the membrane, which is very low in  
dissolved impurities, is referred to as permeate, RO water, or  
product water.  
d. Turbidity less than 1 NTU  
Once the RO water is produced, it is stored in the 6-Gallon RO Water  
Storage Tank. This tank serves two key functions; 1) It acts as a  
buffer between the system and the connected equipment, providing  
ample volumes of water instantaneously, 2) It reduces the on-off  
cycling of the RO system, which produces better quality water, and  
prolongs the system’s life.  
Printed in U.S.A.  
EV3128-25 Rev A SE08